Mass And Energy Balance For Fixed Bed Incinerators A case of a locally designed incinerator in Tanzania

dc.contributor.authorOmari, Arthur
dc.contributor.authorNjau, Karoli N.
dc.contributor.authorJohn, Geoffrey R.
dc.contributor.authorKihedu, Joseph H.
dc.contributor.authorMtui, Peter L.
dc.date.accessioned2016-06-17T19:39:50Z
dc.date.available2016-06-17T19:39:50Z
dc.date.issued2015-10
dc.description.abstractAn estimation of mass and energy balance of an incinerator is an important consideration toward the design and operation of the incineration process. This paper is aimed to study the mass and energy balance of a locally made fixed bed incinerator. The results shows that the total mass rate of 49 kg/h of municipal solid waste and 9.75 kg/h of diesel consumed 458.9 kg/h of air. The incineration process generates 379,287.14 kJ/h with ash and flue gases emissions at a total mass rate of 528.51 kg/h.en_US
dc.identifier.issn3159-0040
dc.identifier.urihttp://hdl.handle.net/20.500.11810/2538
dc.language.isoenen_US
dc.publisherJMESTen_US
dc.subjectIncineratorsen_US
dc.subjectTanzaniaen_US
dc.titleMass And Energy Balance For Fixed Bed Incinerators A case of a locally designed incinerator in Tanzaniaen_US
dc.typeJournal Articleen_US
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Mass And Energy Balance For Fixed Bed Incinerators A case of a locally designed incinerator in Tanzania.pdf
Size:
3.18 MB
Format:
Adobe Portable Document Format
Description:
Full Text
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: