Platinum Catalysed Wet Oxidation of Phenol in a Stirred Slurry Reactor: A Practical Operation Window

dc.contributor.authorMasende, Z. P. G.
dc.contributor.authorKuster, B. F. M.
dc.contributor.authorPtasinski, Krzysztof J.
dc.contributor.authorJanssen, Frans J. J. G.
dc.contributor.authorKatima, Jamidu H. Y.
dc.contributor.authorSchouten, J. C.
dc.date.accessioned2016-05-27T13:24:05Z
dc.date.available2016-05-27T13:24:05Z
dc.date.issued2003
dc.description.abstractThe catalytic performance of graphite supported platinum (5 wt.%) catalyst in liquid phase oxidation has been studied using a continuous flow stirred tank slurry reactor (CSTR) in order to determine the proper operation window. The study was carried out in a temperature range of 120–180 °C and in a total pressure range of 1.5–2.0 MPa. Other operational variables employed were oxygen partial pressure (0.01–0.8 MPa), initial phenol feed concentration (0.005–0.07 M), and catalyst concentration from 1 to 10 kg m−3. It was found that the extent of oxygen coverage on the platinum surface determines the reaction pathway and selectivity to CO2 and H2O. Complete oxidation of phenol to CO2 and H2O could be achieved at 150 °C when the reaction proceeds within the range of weight specific oxygen loads of 0.15–0.35 mol s−1 kgPt−1 and at stoichiometric oxygen excess in the range of 0–80%. The activity of the platinum catalyst remained high when the residual partial pressure of oxygen in the reactor was kept below 150 kPa. Higher residual oxygen partial pressure resulted into deactivation of the platinum catalyst (over-oxidation), which was temporary and could be reversed at reducing conditions. The formation of p-benzoquinone, followed by the formation of polymeric products was also favoured at higher oxygen load, which resulted into permanent deactivation of the platinum catalyst (poisoning). While the platinum surface was vulnerable to poisoning by carbonaceous compounds when insufficient oxygen was used, a fully reduced platinum surface favoured the formation of acetic and succinic acids which are difficult to oxidize. Higher temperatures can enhance the activity of the platinum catalyst, while at lower temperatures catalyst deactivation occurs with increased formation of polymeric products and lower selectivity to CO2 and H2O. In order to maintain the catalyst within the proper operation window, a CSTR is the preferred reactor.en_US
dc.identifier.citationMasende, Z.P.G., Kuster, B.F.M., Ptasinski, K.J., Janssen, F.J.J.G., Katima, J.H.Y. and Schouten, J.C., 2003. Platinum catalysed wet oxidation of phenol in a stirred slurry reactor: A practical operation window. Applied Catalysis B: Environmental, 41(3), pp.247-267.en_US
dc.identifier.doi10.1016/S0926-3373(02)00164-9
dc.identifier.urihttp://hdl.handle.net/20.500.11810/2295
dc.language.isoenen_US
dc.publisherElsevieren_US
dc.subjectCatalytic wet oxidationen_US
dc.subjectPhenol oxidationen_US
dc.subjectPlatinum catalysten_US
dc.subjectOperation windowen_US
dc.subjectCatalyst deactivationen_US
dc.titlePlatinum Catalysed Wet Oxidation of Phenol in a Stirred Slurry Reactor: A Practical Operation Windowen_US
dc.typeJournal Articleen_US
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Platinum Catalysed Wet Oxidation of Phenol in a Stirred Slurry Reactor.pdf
Size:
108.79 KB
Format:
Adobe Portable Document Format
Description:
Abstract
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: